    The wrong of SW3 stray light flag processing at the scan edge
    A
    There was wrong processing at the scan edge of the IRS/SW3.
    SW3 (250m) is observation data with a different resolution from SW1,2,4 (1km), but it was wrong processed in low-resolution resampling of the stray light flag.

    [Target product/dataset]
    • L1B product (SW3) : Extended_area / Stray_sign_flag_1km_SWI
    • Low resolution resampling product (SW3) : Image_data / Lt_SW03 (upper 2bit / stray light flag)
    [Target product version] Ver.2000 - 2004
    [Target period] 2018/01/01 - 2022/03/08

    The modified algorithm (Ver.2005) had updated on March 8, 2022.

    Supplement:
    • The brightness value and stray light flag of the L1B (Image_data/Lt_SW03) products are no effect.
    • VNR products are no effect because there is no corresponding processing.
    • SW1,2,4 is no effect because the resolution is 1km (No low-resolution resampling).
    • TIR is not correcting stray light, so there is no effect.
    Last update: 2022/04/22